Credit Optimize Energy Performance
Use the registration-specific energy edition; the 2024 Update sums an energy metric and GHG metric.12
Reviewed · Spot an error? Report it
Points
Up to 25 points. In the 2024 Update that is Table 1 maximum 13 plus Table 2 maximum 12; the duplicated last GHG row does not conflict with this total.2
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Preparation checklist: Registration/date and envelope-route decision, early target and efficiency analysis.
- Preparation checklist: Baseline/proposed tenant model outputs and separate Table 1/Table 2 calculations; renewable contracts and allocations if claimed.
- Preparation checklist: For the original prescriptive route, lighting power density calculations, ENERGY STAR appliance percentage and, as applicable, envelope, HVAC efficiency and control-device records; Retail adds process equipment efficiencies.
Worked example
Assume a 2024 Update Sections a-e project has verified 25% source-energy and 25% GHG improvement. Each table yields 8 points, so 8 + 8 = 16. A Section f project at the same improvements would use different thresholds. Full prerequisite, model and renewable accounting still apply.2
Requirements
For the 2024 Update, establish a source-energy target by schematic design, analyze load/HVAC efficiency and use the Minimum Energy Performance tenant simulation criteria. Add Table 1 points for cost or source energy to Table 2 points for GHG improvement. Use the baseline-envelope Sections a-e or Section f column consistently. The official 2024 paths resource also lists v4.1 Option 2 Prescriptive Compliance for these registrations, up to 17 points using ASHRAE 90.1-2016 and/or Advanced Energy Design Guides. Approved equivalents for tenant simulation include ASHRAE 90.1-2013 or IECC 2015 (LI 10481), Title 24-2016 (LI 10480) and NECB 2011.23
For Sections a-e, both tables award 1-8 points at 8/10/12/14/16/19/22/25% improvement. Table 1 then awards 9/10/11/12/13 at 28/31/34/37/40%; Table 2 awards 9/10/11/12 at 30/35/40/50%. Section f thresholds are two percentage points higher. The current Table 2 repeats the final 12-point 50%/52% row; it does not state a thirteenth GHG point.2
For pre-March 1, 2024 registrations, the original simulation table ranges from 4 points at 4% improvement to 25 at 28%, with its stated intermediate thresholds. The original prescriptive route allows up to 16 points from base-building systems, HVAC controls, lighting and eligible equipment; Retail has additional process-equipment requirements. Do not combine original and 2024 point tables.12
FAQ
Does the repeated 12-point GHG row create a 13-point GHG tier?
No such tier is stated. Keep the published 12-point maximum.2
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.