SSc6 Light Pollution Reduction
Limit exterior uplight, backlight, glare, and internally illuminated signage for the project's lighting zone and installation geometry.1
- Points
- See below
- Applies to
- BD+C
Reviewed · Spot an error? Report it
Points
NC and Core and Shell: 1 point for all applicable requirements. Maximum uplight ratings are U0 in LZ0/LZ1, U2 in LZ2, U3 in LZ3, and U4 in LZ4; also satisfy the separate backlight/glare table.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Exterior lighting plan and MLO lighting-zone determination
- Luminaire schedule and BUG photometric reports for the installed sources
- Lighting-boundary, mounting-height, distance, and orientation calculation
- Exemption and separate-control schedule; internally illuminated signage details with evidence of maximum nighttime luminance
Worked example
Assume a site is validly classified LZ2 and all applicable luminaires have U1. Because U1 is below the U2 cap, the uplight check passes. This does not establish backlight, glare, or signage compliance; these require separate review.1
Requirements
Apply the MLO lighting-zone uplight limits and the backlight/glare limits determined by mounting height, distance from the lighting boundary, and orientation. Address all exterior luminaires inside the project boundary. The listed exemptions apply only when separately controlled; an exempt light is not a blanket exemption for the whole site. Internally illuminated exterior signage must also stay within the nighttime luminance limits in Table 3: 50 cd/m² in LZ0 and LZ1, 100 in LZ2, 200 in LZ3, and 350 in LZ4.1
FAQ
Can one acceptable BUG rating be applied to the entire site?
No. Check each applicable luminaire's installed source and location against the zone and geometry criteria.1
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.
- LEED v5 BD+C Rating SystemJuly 2026 · SSc6, printed pp. 51-53
Maintained by VERTIQ, LEED software for consultants.