Credit Construction and Demolition Waste Management
Use a complete diversion route or the ID+C waste-generation limit, keeping one consistent measurement basis.1
Reviewed · Spot an error? Report it
Points
| Points | Requirement |
|---|---|
| 1 | 50% diversion and three streams |
| 2 | 75% and four streams |
| 2 | Waste-generation route |
Do not add the alternative routes.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Preparation checklist: Waste tickets, unit basis, destinations, total/disposed/diverted report and stream classification.
- Preparation checklist: For commingled averages, dated receipts and matching facility recovery-rate evidence; supporting standards evidence for any conditional WtE claim.
- Preparation checklist: For project-specific commingled rates, weight of each load, sorted recyclable and residual weights, the measurement method, and supporting tickets, calculations, photographs and dates.
Worked example
Assume 100 tonnes of eligible C&D waste with 75 tonnes documented diverted across four qualifying streams, and no ADC counted as diversion. The ratio is 75/100 = 75%, corresponding to the 2-point diversion route. A commingled facility-average load alone cannot be relabeled four streams.12
Requirements
For diversion, recycle/salvage nonhazardous C&D waste and use consistent weight or volume throughout. Exclude excavated soil and land-clearing debris; alternative daily cover remains disposal. Divert at least 50% with three streams, or 75% with four. The October 2026 supplement also excludes landscaping materials from diversion calculations for projects registered on or after November 9, 2020.12
The alternative waste-generation route limits construction waste to 2.5 lb/square foot (12.2 kg/square meter). The October 2026 supplement applies to registrations on/after November 9, 2020. For commingled averages, retain receipt dates and matching facility rates and count the load as one stream. LEED v4 also allows project-specific commingled loads to claim each recyclable material as a separate stream when the recovery facility physically sorts the load and load, stream and residual weights are tracked and verified. It accepts measured volume-to-weight methods, not visual estimates; biomass/wood-derived fuel is distinct from WtE. Conditional v4 WtE requires exhausted reuse/recycling opportunities and the stated European standards; it is not automatically an international-only route.12
FAQ
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.
- LEED v4 for Interior Design and ConstructionUpdated July 25, 2019 · Construction and Demolition Waste Management; printed and PDF pp. 51
- USGBC Commingled (Mixed) Construction and Demolition Recycling Rate ReportingOctober 2026 · PDF pp.1-4; Table 1 facility averages, Table 3 measurement/diversion and definitions; PDF pp.1-4; Table 1 facility averages, Table 2 project-specific rates, Table 3 measurement/diversion and definitions
Maintained by VERTIQ, LEED software for consultants.