Prerequisite Environmental Tobacco Smoke Control

Locate the tenant project in a building with the required indoor and outdoor smoke prohibition.1

Points
Required
Applies to
ID+CBD+C
Other versions
v4.1
VERTIQ reference ID
EQp2

Reviewed · Spot an error? Report it

Points

Required prerequisite, with no points.1

Documents to prepare

Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.

  • Preparation checklist: Building smoke policy, lease/owner confirmation and designated-area plan.
  • Preparation checklist: Entrance-signage locations and code evidence if a prohibition cannot be implemented.

Worked example

Assume a designated smoking area is 30 feet from every relevant entry, intake and operable window. It exceeds the 25-foot separation by 5 feet. The building-wide policy, business-use-area rule and entrance signage still need verification.1

Requirements

Prohibit smoking inside the building and outside except in designated areas at least 25 feet (7.5 meters) from entries, outdoor intakes and operable windows. Include business-use areas outside the property line. If code prevents the 25-foot prohibition, document the regulation. Post no-smoking-policy signage within 10 feet (3 meters) of every entrance.1

FAQ

Is a smoke-free tenant suite enough if the rest of the building permits smoking?

The stated prerequisite requires locating in a building with the specified prohibition, not only a smoke-free tenant suite.1

Sources

This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.

  1. LEED v4 for Interior Design and ConstructionUpdated July 25, 2019 · Environmental Tobacco Smoke Control; printed and PDF pp. 54