Prerequisite Environmental Tobacco Smoke Control

Prevent smoke exposure through the required smoking policy, separation and signage.1

Points
Required
Applies to
BD+CID+C
Other versions
v4.1
VERTIQ reference ID
EQp2

Reviewed · Spot an error? Report it

Points

Required prerequisite; no points.1

Documents to prepare

Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.

  • No-smoking policy and lease language where applicable
  • Site plan with smoking-area distances
  • Signage plan/photographs
  • Residential compartmentalization and leakage test records if used

Worked example

Assume an outdoor smoking area lies 9 m from the entry but 5 m from an operable window. The minimum separation is 5 m, below 7.5 m, so the entry distance alone does not establish the standard path.1

Requirements

The standard path prohibits indoor smoking and limits outdoor smoking to designated areas at least 7.5 m from entries, outdoor-air intakes and operable windows, with the stated local-code exception. Post the required entry signage. Schools prohibit smoking across the site. Residential projects using the alternative need the specified common-area policy, compartmentalization and leakage verification.1

FAQ

Is a smoking area acceptable just because it is far from the main entrance?

Check every relevant entry, air intake and operable window, as well as applicable off-property business-use areas.1

Sources

This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.

  1. LEED v4 BD+C Rating SystemUpdated July 25, 2019 · Environmental Tobacco Smoke Control prerequisite, printed/PDF pp. 110-111