Credit Interior Lighting

Apply the CI/Hospitality options or the separate Retail control requirements.1

Points
See below
Applies to
ID+CBD+C
Other versions
v4.1
VERTIQ reference ID
EQc6

Reviewed · Spot an error? Report it

Points

CI/Hospitality: 1 point per option, maximum 2. Retail: 2 points for its separate requirements.1

Documents to prepare

Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.

  • Preparation checklist: Adaptation and space classification, lighting-control plans and schedules.
  • Preparation checklist: For quality, four selected strategies with luminaire data and reflectance/illuminance calculations.

Worked example

Assume a CI project has 50 individual occupant spaces and 46 have compliant three-level controls. The share is 92%, above 90%. That establishes only the individual-space portion of the 1-point control option, not the shared-space provisions or four quality strategies.1

Requirements

For CI/Hospitality, Option 1 gives at least 90% of individual occupant spaces three-level controls (on/off/midlevel 30-70%). All shared spaces need multizone three-level control, separate presentation-wall control and in-space controls with sightlines. Hospitality guest rooms are excluded as stated. Museum exhibit and other collection spaces may be excluded from the interior lighting requirements.12

CI/Hospitality Option 2 selects four of eight quality strategies, covering luminance, CRI, lamp life, direct-only lighting, reflectance and illuminance ratios, with each strategy scope and dependencies. Retail provides individual controls to at least 90% of individual occupant spaces in office and administrative areas. Follow the Option 1 step-by-step guidance for those areas. In sales areas, provide at least three lighting levels: on, off and midlevel.12

FAQ

Can Retail assume it follows the same four-strategy quality option?

Retail has its own stated control route; do not substitute the CI/Hospitality option structure.1

Sources

This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.

  1. LEED v4 for Interior Design and ConstructionUpdated July 25, 2019 · Interior Lighting; printed and PDF pp. 68-69
  2. LEED v4 Reference Guide for Interior Design and Construction AddendaCumulative through February 20, 2026 · PDF p.57, Reference Guide p.400, July 8, 2017 Retail three-level-control clarification; PDF p.49, July 29, 2022 Museums entry; PDF p.57, Reference Guide p.400, July 8, 2017 Retail three-level-control clarification

Maintained by VERTIQ, LEED software for consultants.