Credit Sensitive Land Protection
Keep the development footprint away from sensitive land or use previously developed land.1
- Points
- See below
- Applies to
- BD+C
- VERTIQ reference ID
- LTc2
Reviewed · Spot an error? Report it
Points
| Points | Requirement |
|---|---|
| 1 | Most adaptations |
| 2 | Core and Shell |
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Previous-development evidence
- Site and development-footprint plans
- Flood, habitat, wetland and water-body maps
- Soil/farmland classification documents where applicable
Worked example
Assume all 4,000 m2 of a development footprint is on qualifying previously developed land. Coverage = 4,000 / 4,000 = 100%, supporting Option 1; an undocumented remainder would need a separate sensitivity review.1
Requirements
Option 1 locates the development footprint on previously developed land. Option 2 applies the listed farmland, floodplain, habitat, water-body and wetland exclusions to other land, with narrowly defined minor-improvement exceptions. Use local equivalents where the source allows them.1
FAQ
Is a vacant parcel automatically previously developed?
No. Document the site's development history rather than treating vacancy as proof.1
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.
- LEED v4 BD+C Rating SystemUpdated July 25, 2019 · Sensitive Land Protection, printed/PDF pp. 12-13