Credit Quality Views
Provide qualifying exterior views with the required area coverage and view characteristics.1
Reviewed · Spot an error? Report it
Points
1 point generally; Healthcare up to 2 through its adaptation provisions.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- View-line and regularly occupied-area plans
- Glazing specifications
- View characteristic photographs/diagrams
- Warehouse or Healthcare area schedule where applicable
Worked example
Assume 1,000 m2 standard regularly occupied area, of which 800 m2 has both a qualifying exterior view and at least two listed view characteristics. Coverage = 80%, exceeding 75%. A simple glazing-area ratio would not demonstrate the same result.1
Requirements
For the standard path, at least 75% of regularly occupied floor area needs a direct exterior line of sight through clear vision glazing and at least two listed view characteristics. Include permanent obstructions and apply limits on interior-atrium views. Warehouses distinguish office and distribution areas. Healthcare uses separate inpatient and perimeter-area criteria.1
FAQ
Does any window automatically provide a qualifying view?
No. Glazing clarity, obstructions, line of sight and the listed view characteristics all matter.1
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.
- LEED v4 BD+C Rating SystemUpdated July 25, 2019 · Quality Views, printed/PDF pp. 134-135
Maintained by VERTIQ, LEED software for consultants.