Credit Quality Views
Provide qualifying outdoor views for the required occupied-area share.1
Reviewed · Spot an error? Report it
Points
1 point generally; Healthcare can earn 1 point for inpatient units and 1 for other areas, up to 2.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- View-area plan and regularly occupied-area schedule
- Glazing VLT product data
- Sightline/head-height sections and view-content photographs
- Healthcare perimeter-area calculations if applicable
Worked example
Assume an NC project has 2,000 m2 of eligible regularly occupied floor area and 1,600 m2 meets every view criterion. Coverage = 80%, exceeding 75%. A clear sightline through glass with VLT 35% would not qualify under this route.1
Requirements
The general route serves 75% of regularly occupied floor area through glazing with VLT above 40%, with qualifying view content and direct access within three times glazing head height. Eligible interior atrium views can cover up to 30% of the required area. Warehouses use the general office rule and 25% of bulk storage/sorting/distribution area. Healthcare has separate inpatient and perimeter-area components.1
FAQ
Does any window count as a quality view?
No. Glazing transmission, direct access, distance and view-content conditions must also be met.1
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.
- LEED v4.1 BD+C Rating SystemFebruary 2025 download; cover dated July 28, 2023 · Printed and PDF pp. 137-138
Maintained by VERTIQ, LEED software for consultants.