Prerequisite Indoor Water Use Reduction
Reduce aggregate water use from eligible tenant fixtures and fittings by at least 20%, and meet the applicable product-label, appliance and process requirements. This is an ID+C prerequisite with no points.1
Reviewed · Spot an error? Report it
Points
Required prerequisite; 0 points. A 20% arithmetic reduction alone does not establish product-label or process compliance.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Preparation checklist: Fixture schedule with flow/flush ratings, locations, occupant assumptions, baseline and design calculations.
- Preparation checklist: WaterSense or accepted local-equivalent evidence for applicable new products; appliance and process compliance records.
- Preparation checklist: Where local code overrides a LEED fixture requirement, an excerpt of the local code highlighting the flow rate requirements.
Worked example
Assume the eligible fixture inventory has calculated baseline demand of 100,000 gallons/year and proposed demand of 78,000 gallons/year using the same occupancy and use assumptions. Reduction = (100,000 - 78,000) / 100,000 x 100 = 22%. This clears the 20% reduction test; the applicable labels and appliance/process checks still require separate evidence.1
Requirements
Use the Table 1 baseline for the fixtures within the project scope: toilets 1.6 gpf, urinals 1.0 gpf, public lavatory faucets 0.5 gpm, private lavatory and kitchen faucets 2.2 gpm, and showers 2.5 gpm. Calculate aggregate demand using the actual fixture inventory and consistent occupant and use assumptions. Where local standard supply pressure differs from the LEED baseline pressure, the Guide permits calculating flow fixture water use at the local pressure. Product cutsheets must show compliance with the LEED baseline flow rate; projects without manufacturer data at the LEED pressure use local pressure in the design case and LEED baseline flow rates in the baseline case.1
Newly installed eligible toilets, urinals, private lavatory faucets and showerheads need WaterSense labels or a local equivalent outside the United States. Where local code conflicts with these requirements, a team may select code-compliant fixtures at the lowest flow rate the code allows and compensate with more efficient fixtures, provided the aggregate 20% reduction is met. Projects whose fixtures and fittings are not within tenant spaces are exempt from this prerequisite.1
Check appliances, cooling and other processes within the project scope separately. Existing appliances intended for reuse are exempt from Table 2. Newly installed applicable appliances must meet Table 2, which accepts ENERGY STAR or a performance equivalent, with the EU A label acceptable for residential appliances in Europe, and potable once-through cooling is prohibited. Cooling towers need makeup meters, conductivity controls, overflow alarms and compliant drift eliminators. Retail and Hospitality also have the additional kitchen and process requirements in Tables 4 and 5.1
FAQ
Does using only fixtures outside the tenant space automatically earn the water credit?
No. The prerequisite exemption is limited to this prerequisite. The Indoor Water Use Reduction credit includes fixtures necessary to serve occupants, including fixtures outside the tenant space.1
Can reused appliances be treated the same as newly purchased appliances?
The Guide exempts existing appliances intended for reuse from Table 2. Identify them explicitly rather than omitting the appliance scope.1
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.
- LEED v4.1 Interior Design and Construction GuideNovember 2025 · Indoor Water Use Reduction prerequisite, printed/PDF pp. 29-32; ID+C scorecard printed/PDF pp. 5-6; Indoor Water Use Reduction credit occupant-serving fixture scope, printed/PDF p33
Maintained by VERTIQ, LEED software for consultants.