Credit Bicycle Facilities

Connect the project to a useful bicycle network and provide the adaptation-specific bicycle storage and shower provisions.1

Points
1 point
Applies to
ID+CBD+C
Other versions
v4
VERTIQ reference ID
LTc4

Reviewed · Spot an error? Report it

Points

1 point. The network, storage, access and applicable shower/program requirements work together.1

Documents to prepare

Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.

  • Preparation checklist: Bicycle network/destination and storage walking-route maps with occupant/visitor counts.
  • Preparation checklist: Separate storage-capacity calculations, shower/changing plans and Retail program evidence where applicable.

Worked example

Assume a Commercial Interiors project has 80 regular occupants and 40 peak visitors. Long-term storage = max(2, 0.05 x 80) = 4 spaces. Short-term storage = max(2, 0.025 x 40) = 2 spaces. The first-100-occupant shower rule requires one shower/changing facility. The network and placement requirements must also be met.1

Requirements

A functional entry and/or bicycle storage must be within 200 yards (180 m) of a bicycle network connecting to at least 10 diverse uses or a qualifying BRT/rail/ferry destination, all within a 3-mile (4,800 m) bicycle distance. Qualifying planned lanes/trails must be fully funded at occupancy and scheduled for completion within three years.1

Commercial Interiors and Hospitality provide short-term storage for at least 2.5% of peak visitors, minimum two spaces, and long-term storage for at least 5% of regular occupants, minimum two, in addition. Short-term storage is within 200 ft walking distance of a main entrance; long-term is within 300 ft of a functional entry. Do not double allocate capacity.1

Commercial Interiors and Hospitality also provide on-site showers with changing facilities: one for the first 100 regular occupants and one for each additional 150, with the Guide graduated increments for large occupancies. Retail uses two short-term spaces per 5,000 ft2, minimum two per tenant space, and long-term storage for at least 5% of regular occupants, minimum two per building; it also needs an employee bicycle maintenance program or route assistance for employees and customers, and its requirements do not include showers. LEED for Neighborhood Development Location mutual exclusion applies.1

FAQ

Can the same rack capacity be allocated fully to two projects?

No. Bicycle storage capacity cannot be double-counted.1

Can storage alone earn the credit?

No. Demonstrate the network, location and applicable shower/program requirements too.1

Sources

This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.

  1. LEED v4.1 Interior Design and Construction GuideNovember 2025 · Bicycle Facilities, printed/PDF pp. 22-25; ID+C scorecard printed/PDF pp. 5-6

Maintained by VERTIQ, LEED software for consultants.