Credit Bicycle Facilities

Provide a qualifying bicycle-network connection plus storage and applicable shower/changing facilities.1

Points
1 point
Applies to
BD+CID+C
Other versions
v4
VERTIQ reference ID
LTc6

Reviewed · Spot an error? Report it

Points

1 point.1

Documents to prepare

Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.

  • Bicycle-network and destination map
  • Peak visitor/regular occupant calculations
  • Bicycle storage layout and equipment schedule
  • Shower/changing-room plans, plus the Retail bicycle maintenance or route-assistance program description where applicable

Worked example

Assume a commercial project has 200 peak visitors and 100 regular occupants. Required storage is at least 5 short-term spaces and 5 long-term spaces: 200 x 2.5% and 100 x 5%, each above the four-space minimum. One shower is required for the first 100 regular occupants. Network and distance tests remain separate.1

Requirements

For the general route, the project entry/storage must be within 180 m of a bicycle network connecting to qualifying destinations within 4.8 km. Commercial/institutional storage requires short-term spaces for 2.5% of peak visitors and long-term spaces for 5% of regular occupants, with four-space minimums. Storage location, showers and larger-occupancy rules also apply. Residential, Schools, Retail and Healthcare have special counts or destination rules; do not apply the commercial formula to every adaptation.1

FAQ

Can shared storage be counted twice?

No. Capacity already fully allocated to other facilities cannot also serve this project's occupants.1

Sources

This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.

  1. LEED v4.1 BD+C Rating SystemFebruary 2025 download; cover dated July 28, 2023 · Printed and PDF pp. 25-27

Maintained by VERTIQ, LEED software for consultants.