Credit Quality Views
Provide qualifying direct outdoor views for at least 75% of regularly occupied floor area, with the required glazing, view content and occupant distance.1
Reviewed · Spot an error? Report it
Points
1 point at the 75% qualifying-area threshold with all view conditions satisfied.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Preparation checklist: Regularly occupied floor plan, permitted exclusions and direct-view area calculations.
- Preparation checklist: View sections/sightlines, glazing VLT and pattern/tint data, exterior view content and head-height/distance checks.
Worked example
Assume the project has 1,000 m2 of regularly occupied floor area after permitted exclusions. A documented 780 m2 has compliant direct exterior views, glazing and occupant distance. Coverage = 780 / 1,000 x 100 = 78%, above 75%. No interior-atrium contribution is assumed.1
Requirements
Provide views to the outdoor natural or urban environment for at least 75% of regularly occupied floor area. Auditoriums, dedicated video-conference rooms and gymnasiums may be excluded. Interior atria may contribute to no more than 30% of the required qualifying area.1
Views pass through glazing with visible-light transmittance above 40%, preserving the view through patterns/tints. They include nature, urban landmarks or art, or objects at least 25 ft (7.5 m) from the glazing exterior. Occupants need direct view access within three times the glazing head height.1
FAQ
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.