Credit Indoor Water Use Reduction
Earn points for fixture savings above the indoor-water prerequisite, with different point limits by BD+C adaptation.1
Reviewed · Spot an error? Report it
Points
Maximums: NC, Data Centers, Warehouses and Distribution Centers, and Hospitality 6; Core and Shell 4; Schools, Retail and Healthcare 7.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Completed indoor water use calculator
- Fixture schedule and product data
- Alternative-water supply calculation where claimed
- Appliance/process equipment schedules and qualifying service-volume records
Worked example
Assume an NC project has 100,000 gallons/year baseline and 63,000 gallons/year design consumption under the accepted calculation. Reduction = 37%. It reaches the 35% row for 3 points but not the 40% row for 4 points. This example assumes all prerequisite and calculation-scope requirements are met.1
Requirements
Use the prerequisite's baseline and include the fixtures needed by project occupants, including applicable fixtures outside the project boundary. Alternative water may provide additional potable-water savings.1
For general BD+C, 25%, 30%, 35%, 40%, 45% and 50% reductions correspond to 1 through 6 points. Core and Shell stops at 4 points for 40%. The Schools, Retail, Hospitality and Healthcare column stops at 5 points for 45%; qualifying appliance/process tables can add points under the adaptation-specific rules. Schools, Retail and Healthcare can earn two such additional points, while Hospitality can earn one. Review minimum laundry, meal-service, medical/laboratory or steam-system applicability before claiming those points.1
FAQ
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.
- LEED v4.1 BD+C Rating SystemFebruary 2025 download; cover dated July 28, 2023 · Printed and PDF pp. 59-61
Maintained by VERTIQ, LEED software for consultants.