WEp2 Minimum Water Efficiency

LEED v5 BD+C WEp2 combines fixture and fitting efficiency, equipment water efficiency and outdoor water efficiency; the fixture performance path requires a 20% aggregate reduction from its specified baseline.1

Points
Required
Applies to
BD+CID+C

Reviewed · Spot an error? Report it

Points

WEp2 is required for New Construction and Core and Shell and awards no points. Enhanced Water Efficiency is a separate credit.1

Documents to prepare

Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.

  • Plumbing fixture schedules and manufacturer specifications showing installed flow and flush rates.
  • Fixture water calculation report documenting baseline and proposed annual aggregate use and consistent occupancy assumptions.
  • Equipment schedules and manufacturer specifications covering applicable appliances and process-water systems.
  • Landscape plan and irrigation calculation, or evidence that no permanent irrigation is required beyond the establishment period.

Worked example

Illustrative fixture performance-path totals: baseline annual use = 1,000,000 liters; proposed annual use = 780,000 liters. Aggregate reduction = (1,000,000 - 780,000) / 1,000,000 × 100 = 22%, exceeding the 20% fixture threshold. Equipment and outdoor requirements still need separate checks; this example does not establish complete prerequisite compliance.1

Requirements

For new and existing fixtures and fittings within the project boundary, meet the maximum rates in Table 1 or demonstrate a 20% aggregate reduction from the Table 2 baseline.1

Newly installed appliances, equipment and processes must meet Tables 3 and 4; existing appliances and equipment may be excluded from this equipment assessment.1

For outdoor water, demonstrate no permanent irrigation beyond a maximum two-year establishment period, or reduce the annual theoretical irrigation requirement by at least 30% through plant selection and irrigation efficiency.1

Core and Shell requirements cover base-building fixtures, appliances, equipment, process water and outdoor water; the tenant-guideline provision also applies.1

FAQ

Does a 20% fixture reduction satisfy the whole prerequisite?

No. Fixture efficiency, equipment water efficiency and outdoor water efficiency are joined by AND in the pathway table.1

Can dual-flush toilets use a weighted average?

No. The full-flush volume must be no greater than 1.28 gallons or 4.8 liters; the table footnote disallows a weighted average.1