MRp2 Quantify and Assess Embodied Carbon

Quantify the A1-A3 global warming potential of structure, enclosure, and hardscape materials, identify the top three carbon sources, and explain the reduction strategies considered. This prerequisite does not award points or require a particular reduction percentage.1

Points
Required
Applies to
BD+CID+C

Reviewed · Spot an error? Report it

Points

Required for NC and Core and Shell; 0 points. Quantification plus assessment of the three largest sources is required.1

Documents to prepare

Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.

  • Material quantity takeoff or bill of quantities covering structure, enclosure, hardscape, and ancillary structures
  • GWP source documents with declared units and A1-A3 scope, or an LCA tool report
  • Material-by-material quantity and GWP calculation workbook
  • Top-three embodied-carbon source assessment and design-strategy narrative
  • Tenant guidelines listing measurements and suppliers for Core and Shell

Worked example

Assume a teaching example with concrete at 100 m³ × 250 kgCO2e/m³ = 25,000 kgCO2e; steel at 10 tonnes × 1,500 kgCO2e/tonne = 15,000 kgCO2e; and glass at 200 m² × 30 kgCO2e/m² = 6,000 kgCO2e. The subtotal is 46,000 kgCO2e, or 46 tonnes CO2e. The example uses assumed A1-A3 factors, covers only three materials, and is not a complete project inventory. A complete inventory must be ranked before selecting the actual three hot spots.1

Requirements

Include ancillary structures within the LEED boundary, including parking structures and outbuildings. At minimum address asphalt, concrete, masonry, structural steel, insulation, aluminum extrusions, structural wood and composites, cladding, and glass. Calculate each material's cradle-to-gate GWP per unit multiplied by the quantity used, or report A1-A3 results from an LCA or embodied-carbon tool.1

Identify the three largest sources and describe project-specific strategies considered for them. Core and Shell projects communicate the measurements and material suppliers in tenant guidelines. MRc2 has separate reduction and EPD-path requirements; do not substitute those for this quantification requirement.1

FAQ

Does quantifying carbon automatically earn MRc2 points?

No. MRp2 establishes quantification and hot-spot assessment. MRc2 is a separate credit with its own achievement requirements.1

Can a tool report replace multiplication of every line item?

The rating system permits reporting A1-A3 results from an LCA or embodied-carbon software tool, provided the required project scope is covered.1