Prerequisite PBT Source Reduction: Mercury
Reduce mercury in Healthcare equipment, lamps and waste handling.1
- Points
- Required
- Applies to
- BD+C
- Other versions
- v4.1
- VERTIQ reference ID
- MRp3
Reviewed · Spot an error? Report it
Points
Required for Healthcare; no points.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Healthcare mercury-containing equipment inventory
- Lamp schedule and mercury-content data
- Mercury recycling/phase-out plan
- Exit-sign specifications
- Dental amalgam separator certification where relevant
Worked example
Assume a proposed illuminated exit sign is mercury-free and rated 4 W. It meets the sign's below-5-W screen, while the complete equipment, lamp and recycling requirements remain separate.1
Requirements
Identify mercury-containing products, collection procedures and disposal methods in the recycling system. Follow the stated new-construction/renovation mercury-elimination requirements, lamp restrictions and lamp-type mercury limits. Dental facilities need qualifying amalgam separators. Exit signs must contain no mercury and use less than 5 W.1
FAQ
Does this prerequisite ban every mercury-containing lamp?
The source applies type-specific restrictions and limits rather than treating every permitted lamp type identically.1
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.