Credit Design for Flexibility
Use at least three eligible Healthcare strategies for future adaptation and expansion.1
Reviewed · Spot an error? Report it
Points
1 point for Healthcare; three qualified strategies are required.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Flexibility strategy narrative and matrix
- Departmental gross-area plan
- Shell/soft space and expansion drawings
- Demountable partition/modular casework specifications
Worked example
Assume departmental gross area is 10,000 m2. A shell-space strategy needs at least 10,000 x 5% = 500 m2 in the required location and configuration. That qualifies only one strategy; two additional complete listed strategies are still needed.1
Requirements
Choose at least three listed strategies and meet each one's quantities and design conditions. Options include interstitial utility distribution, programmed soft space, shell space, horizontal/vertical expansion capacity, future structured parking, demountable partitions and modular casework. Record the future use and continuity assumptions that make the strategy practical.1
FAQ
Can three small partial strategies add up to the credit?
Each of at least three selected strategies must satisfy its own required scope and threshold.1
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.
- LEED v4 BD+C Rating SystemUpdated July 25, 2019 · Design for Flexibility, printed/PDF pp. 104
Maintained by VERTIQ, LEED software for consultants.