Credit PBT Source Reduction: Lead, Cadmium, and Copper
Specify the Healthcare material substitutions and joining methods that reduce lead, cadmium and copper exposure.1
Reviewed · Spot an error? Report it
Points
2 points for Healthcare when the applicable requirements are satisfied.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Plumbing pipe/fitting/solder/flux specifications
- Lead/cadmium declarations for roofing, wiring and paint
- Copper joint installation specification
- Renovation wire disposal record where applicable
Worked example
Assume a specified wire has 250 ppm lead. Since 250 < 300 ppm it meets the wire concentration screen; this alone does not establish the separate plumbing, paint, roofing, copper and renovation conditions.1
Requirements
Apply the stated lead limits for drinking-water plumbing solder, flux and wetted surfaces, and restrictions for roofing/flashing, wire/cable and paint. Avoid intentionally added cadmium in paint. For copper plumbing, use mechanically crimped joints or the specified soldering/flux standards. Radiation lead shielding and MRI copper shielding are exempt; renovation wire removal has a separate disposal condition.1
FAQ
Does a general 'lead-free' label prove every requirement?
No. Verify the credit-specific composition limits and the product's application rather than relying only on the label.1
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.
- LEED v4 BD+C Rating SystemUpdated July 25, 2019 · PBT Source Reduction: Lead, Cadmium and Copper, printed/PDF pp. 101