Credit Building Life-Cycle Impact Reduction
Use an eligible building-reuse pathway or compare the structure and enclosure through whole-building life-cycle assessment.1
Reviewed · Spot an error? Report it
Points
Generally 2-5 points; Core and Shell up to 6. Under area reuse, 25%/50%/75% earns 2/3/4 points, or 2/3/5 for Core and Shell. The WBLCA option earns 3 points.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Existing/demolition/new-work plans
- Retained and total surface-area takeoff
- Historic designation or blight documentation where applicable
- Baseline and proposed WBLCA reports, model scope and dataset versions
Worked example
Assume a qualifying project has 20,000 m2 of counted completed surface area and 10,000 m2 retained or salvaged area. Reuse = 10,000 / 20,000 x 100 = 50%, corresponding to 3 points under Option 3. Excluded window assemblies and remediated hazardous materials must be removed consistently.1
Requirements
The four alternative options cover historic-building reuse, renovation of an abandoned or blighted building, area-based building/material reuse, and WBLCA. Historic or blighted options have specific eligibility and preservation conditions.1
The WBLCA option requires at least 10% reduction in three of six impact categories including global warming potential, with no category increasing more than 5%. Baseline and proposed buildings must be comparable, use the same software/data, and use the same service life of at least 60 years.1
FAQ
Is a 10% GWP reduction alone enough for WBLCA points?
No. At least three impact categories, including GWP, must meet the 10% reduction, and none may increase more than 5%.1
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.
- LEED v4 BD+C Rating SystemUpdated July 25, 2019 · Building Life-Cycle Impact Reduction, printed/PDF pp. 89-91
Maintained by VERTIQ, LEED software for consultants.