Prerequisite Storage and Collection of Recyclables

Provide accessible recycling storage and collection for the building and safely handle selected special wastes.1

Points
Required
Applies to
BD+CID+C
Other versions
v4
VERTIQ reference ID
MRp1

Reviewed · Spot an error? Report it

Points

Required prerequisite; no points.1

Documents to prepare

Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.

  • Recycling storage/collection floor plans
  • Waste-stream service agreement
  • Narrative of recycling storage and collection strategies, including battery, lamp and e-waste handling

Worked example

Assume each floor has labeled recycling bins and a central room accessible to the hauler. Verify the five material streams are actually served and select, for example, batteries plus electronic waste for the two special-waste procedures; a bin count alone does not prove service coverage.1

Requirements

Serve the entire building with dedicated areas accessible to occupants and haulers; collection and storage can be separate. Cover mixed paper, corrugated cardboard, glass, plastics and metals. Also provide safe collection, storage and disposal measures for two of batteries, mercury-containing lamps and electronic waste.1

FAQ

Must collection and storage be in the same room?

No. They may be separate locations if the access and full-building service requirements are met.1

Sources

This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.

  1. LEED v4.1 BD+C Rating SystemFebruary 2025 download; cover dated July 28, 2023 · Printed and PDF pp. 90

Maintained by VERTIQ, LEED software for consultants.