EAc1 Greenhouse Gas Emissions Reduction Performance

Earn points through on-site combustion reductions, qualifying renewables, and total energy-related GHG reductions.1

Points
See below
Applies to
O+M

Reviewed · Spot an error? Report it

Points

Up to 12 points: Option 1 up to 5 at 20/40/60/80/100% reduction; Option 2 up to 4 using the separate tier scale; Option 3 up to 3 at 15/30/60% reduction. Platinum has additional EAc1 conditions in Appendix I.1

Exemplary performance: supplying at least 40% of annual electricity from Tier 1 sources or 100% from Tier 2 sources under Option 2, and/or reaching at least 80% below the GHG emissions target under Option 3, earns 1 exemplary performance point, claimed under Project Priorities (EP12).2

Documents to prepare

Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.

  • Energy-source data and applicable GHG-target calculation
  • Renewable contracts, generation records, and attribute retirement evidence
  • Combustion, emergency-system hours, and district-energy records
  • Green-e certification or equivalency evidence for Tier 3 purchases and commercial operations date for Tier 2 assets

Worked example

Assume the selected targets and evidence are eligible. On-site emissions of 60 against a target of 100 give 40% reduction and 2 points. Documented Tier 1 generation equal to 20% of annual electricity earns 3 renewable points. Total energy GHG at 70 against a target of 100 gives 30% reduction and 2 points. The illustrative sum is 7 points, with each option's conditions checked separately.1

Requirements

Option 1 compares on-site combustion emissions with an eligible NextGen, historical, or intensity target. Its no-combustion automatic route excludes district heating and allows only emergency support systems used less than 200 hours a year. Option 2 uses tier-specific renewable criteria, a three-year commitment or proration that begins no later than the reporting-period start date, retirement of attributes, eligible vintage, and geographic conditions. Option 3 compares total energy GHG with a similar-building or historical target; only documented Tier 1 or 2 electricity receives the stated zero factor. Apply district-energy provisions when relevant.1

FAQ

Do Tier 3 certificates give electricity a zero factor in Option 3?

The stated zero-factor treatment in Option 3 names Tier 1 and Tier 2 documented under Option 2. Do not extend that rule to every renewable procurement tier.1

Sources

This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.

  1. LEED v5 O+M Rating SystemJuly 2026 · EAc1, printed pp. 37-41 (PDF pp. 43-47); scorecard pp. 1-2; Appendix I, printed p. 84
  2. USGBC LEED credit library: Greenhouse Gas Emissions Reduction Performance: Exemplary Performance (EP12)Published Apr 22, 2025; retrieved November 8, 2026 · EP12 requirements