SSp1 Minimize Site Disturbance

Assess and protect the site's vegetation and habitat, and implement erosion and sedimentation controls during construction.1

Points
Required
Applies to
BD+C

Reviewed · Spot an error? Report it

Points

Required for NC and Core and Shell; no points. Both the site assessment and implemented control plan are required.1

Documents to prepare

Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.

  • Preconstruction ecological/site assessment and vegetation survey
  • Habitat exclusion-zone and invasive-species control plan
  • Erosion and sedimentation control plan
  • Site-inspection, storm-event, dewatering, and corrective-action records
  • Compliance-route record for the erosion and sedimentation plan: permit applicability, named local equivalent, or compliance by plan
  • Landscape plan or equivalent evidence showing only native and adapted vegetation not listed as invasive

Worked example

Assume an assessment identifies 12 special-status trees. Protecting 11/12 = 91.67% does not satisfy the requirement to conserve 100% of special-status vegetation. This example does not replace the broader habitat and erosion-control obligations.1

Requirements

Survey special-status vegetation, healthy plant communities, and invasive species before construction. Conserve all special-status vegetation, establish physical exclusion zones for healthy habitat, and plan invasive-species control. Use only native/adapted vegetation that is not listed as invasive.1

Create and implement an erosion/sedimentation plan following the stated EPA 2022 CGP, EU Taxonomy noise/dust provisions, or local equivalent. Include habitat protection, inspections on the prescribed weekly or alternate storm-responsive schedule, daily dewatering inspections when discharge occurs, and immediate correction of failed controls. The CGP size exception is not used.1

FAQ

Can a small site omit erosion controls?

No. The prerequisite applies the stated control requirements regardless of project size.1