MRc3 Low-Emitting Materials
Meet product-category emission criteria and coverage thresholds, using valid product testing or certification and the specified category boundaries.1
Reviewed · Spot an error? Report it
Points
NC: 1 point requires more than 90% in each of paints/coatings, flooring, and ceilings. Two points require that base achievement plus more than 80% in two listed additional categories, or more than 80% furniture. C&S: 1 point for any three listed categories each above 90%. Thresholds are strictly greater than, not equal to, the stated percentages.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Complete installed-product register by category
- Category quantity/cost/area/volume totals and compliant-share calculation
- VOC/furniture/formaldehyde certifications or laboratory reports with purchase dates
- Salvage/reuse records and Core and Shell product-list tenant guidelines where applicable
Worked example
Assume NC and compliant shares of 95% paints/coatings, 92% flooring, and 91% ceilings, using each category's valid calculation basis. All three exceed 90%, reaching the 1-point path. Replacing the ceiling value with exactly 90% would not satisfy the printed greater-than threshold.1
Requirements
Evaluate eligible paints/coatings, adhesives/sealants, flooring, walls, ceilings, insulation, furniture, and composite wood using each category's permitted value basis and exclusions. VOC evidence uses qualifying certification valid at purchase, qualifying independent testing within the stated three-year window, or the specified inherently non-emitting/reused routes. Furniture and composite wood have separate criteria; basic regulatory compliance alone is not equivalent to the ULEF/NAF route. Core and Shell can exclude tenant-installed products and communicates the base-building list in tenant guidelines.1
FAQ
Does a VOC content label alone prove the emissions criterion?
The credit specifies emissions testing/certification routes and distinct category criteria. Verify that the actual document meets the relevant route rather than treating a generic label as sufficient.1
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.
- LEED v5 BD+C Rating SystemJuly 2026 · MRc3, printed pp. 138-142
Maintained by VERTIQ, LEED software for consultants.