EQp3 No Smoking or Vehicle Idling
Implement smoking and vehicle-idling restrictions, communicate them, and provide enforcement or signage. Residential exceptions require additional protection.1
- Points
- Required
- Applies to
- BD+C
Reviewed · Spot an error? Report it
Points
Required for NC and Core and Shell; no points. A policy alone must also have communication and enforcement provisions or prohibitive signage.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- No-smoking and vehicle-idling policies
- Site plan showing designated smoking-area distances
- Occupant communications, signage, and enforcement plan
- Residential compartmentalization test and leakage calculation where smoking is permitted
- Core and Shell tenant guidelines communicating the smoking and vehicle-idling policies and signage
Worked example
Assume an unrestricted local context and a designated outdoor smoking area 6 m from an operable window. Because 6 m is less than 7.5 m, that location does not meet the standard separation. The example assumes no local-code constraint requiring the stated maximum-allowable alternative.1
Requirements
Prohibit indoor smoking with the stated exceptions and restrict outdoor smoking to designated locations at least 25 feet (7.5 m), or the maximum allowed by local code, from entrances, air intakes, and operable windows. Schools prohibit all on-site smoking. Prohibit on-site vehicle idling. Residential projects permitting smoking in dwelling units/private balconies must satisfy the stated unit-compartmentalization testing and leakage requirements.1
Ceremonial cultural practices, which include the combustion of tobacco or other controlled materials, are exempt from the requirements of this prerequisite.2
FAQ
Can a school provide a compliant designated smoking area on site?
School projects must prohibit all smoking on-site.1