Credit Surrounding Density and Diverse Uses

Density and nearby uses can be combined for up to 8 points.1

Points
See below
Applies to
ID+CBD+C
Other versions
v4.1
VERTIQ reference ID
LTc2

Reviewed · Spot an error? Report it

Points

3 or 6 density points plus 1 or 2 use points, up to 8.1

Documents to prepare

Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.

  • Preparation checklist: Density boundary, development areas and supporting calculations.
  • Preparation checklist: Area plan or map showing the project site and the location and type of each use for the uses option. The February 2026 addenda strike walking routes from this documentation row, but the option is still measured by walking distance.

Worked example

Assume verified combined density is 35,000 square feet/acre and eight eligible uses meet all type, category and distance restrictions. The result is 6 + 2 = 8 points, provided LEED for Neighborhood Development Location is not attempted.1

Requirements

For density, assess existing development within a 1/4-mile (400-meter) radius of the project boundary. Use combined density or both residential and nonresidential densities: 22,000 square feet/acre, or 7 dwelling units/acre plus 0.5 FAR, earns 3 points; 35,000, or 12 plus 0.8 FAR, earns 6.1

For diverse uses, the main entrance must be within a 1/2-mile (800-meter) walk of 4-7 eligible public uses for 1 point, or at least 8 for 2. Count no more than two of each use type, use at least three categories, and exclude the building primary use.1

FAQ

Can eight restaurants count as eight uses?

No. Only two uses of one type can count, and at least three categories are required.1

Sources

This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.

  1. LEED v4 for Interior Design and ConstructionUpdated July 25, 2019 · Surrounding Density and Diverse Uses; printed and PDF pp. 9-10
  2. LEED v4 Reference Guide for Interior Design and Construction AddendaCumulative through February 20, 2026 · PDF p. 6, February 20, 2026 correction; Reference Guide p. 55 required documentation