Credit Places of Respite
Healthcare projects provide places of respite for patients and visitors equal to 5% of net usable program area, plus 2% dedicated to staff.1
Reviewed · Spot an error? Report it
Points
1 point, Healthcare only.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Area, patient, visitor, staff, shading and vegetation calculations
- Site plan highlighting qualifying outdoor or indoor places of respite by user group, with access points and distances, proximity to smoking areas, vegetation, vegetated canopy and shaded seating
Worked example
Assume a Healthcare building has 10,000 m2 of net usable program area. Patient and visitor respite = 10,000 x 5% = 500 m2. Dedicated staff respite = 10,000 x 2% = 200 m2. Total = 700 m2. Both areas still need to meet the access, seating, vegetation and smoking-separation conditions.1
Requirements
Healthcare only. Provide places of respite accessible to patients and visitors equal to 5% of the building's net usable program area, plus additional dedicated places of respite for staff equal to 2%. Existing places of respite on the hospital campus may qualify if they meet the requirements.1
Places of respite must be outdoors or in interior atria, greenhouses, solaria or conditioned spaces. Interior spaces may supply up to 30% of the required area if 90% of each qualifying space's gross floor area has a direct line of sight to unobstructed views of nature.1
All areas must be accessible from within the building or within 200 feet (60 meters) of a building entrance or access point, and must be where no medical intervention or direct medical care is delivered. Provide options for shade or indirect sun, at least one seating space per 200 square feet (18.5 square meters) of each respite area, and one wheelchair space per five seating spaces. Horticulture therapy and other clinical or special-use gardens unavailable to all building occupants may supply no more than 50% of the required area. Universal-access natural trails may supply no more than 30%, with the trailhead within 200 feet (60 meters) of a building entrance.1
Outdoor areas must have at least 25% of the total outdoor area vegetated at the ground plane, not counting turf grass, or under an overhead vegetated canopy. They must be open to fresh air, the sky and the natural elements, meet the listed sections of the 2010 FGI Guidelines for signage, and be no closer than 25 feet (7.6 meters) to a smoking area.1
Projects in Canada may consider CSA Z8000 Sections 6.1.9 and 6.2.2 Wayfinding as equivalent to the FGI signage requirement.2
FAQ
Can the staff area count toward the 5% for patients and visitors?
No. The 2% staff area is additional and dedicated to staff.1
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.
- LEED v4 BD+C Rating SystemUpdated July 25, 2019 · Places of Respite, printed/PDF p. 46
- LEED v4 BD+C Reference Guide AddendaCumulative table, February 20, 2026 · Places of Respite, Required Documentation row deleted, addenda PDF p. 27; Requirements, Canada signage entry, addenda PDF p. 28
Maintained by VERTIQ, LEED software for consultants.