Credit Acoustic Performance

Meet acoustic criteria for background noise, sound isolation and other applicable room functions.1

Points
See below
Applies to
BD+CID+C
Other versions
v4.1
VERTIQ reference ID
EQc9

Reviewed · Spot an error? Report it

Points

1 point for eligible standard adaptations and Schools; Healthcare up to 2.1

Documents to prepare

Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.

  • Acoustic design report
  • HVAC noise calculations or measurement logs
  • Partition/door/window sound-isolation specifications
  • Reverberation and sound-system analysis where applicable

Worked example

Assume a School classroom HVAC background level is 34 dBA. It is below the credit's 35 dBA classroom limit, but the sound-transmission conditions still need verification. Subtracting decibels is only a limit comparison, not an acoustic energy summation.1

Requirements

For standard eligible adaptations, address HVAC background noise, sound isolation, reverberation and sound reinforcement/masking using the specified standards and room-type criteria. Schools have tighter classroom HVAC criteria and sound-transmission requirements. Healthcare has separate speech/privacy/background-noise and acoustic-finish/site-noise options. Core and Shell and Retail are not listed as eligible in this edition.1

FAQ

Does an NRC product rating prove all acoustic criteria?

No. Absorption, transmission and HVAC noise are different checks, and their required scope depends on the room and adaptation.1

Sources

This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.

  1. LEED v4 BD+C Rating SystemUpdated July 25, 2019 · Acoustic Performance, printed/PDF pp. 136-139