Credit Acoustic Performance
Meet acoustic criteria for background noise, sound isolation and other applicable room functions.1
Reviewed · Spot an error? Report it
Points
1 point for eligible standard adaptations and Schools; Healthcare up to 2.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Acoustic design report
- HVAC noise calculations or measurement logs
- Partition/door/window sound-isolation specifications
- Reverberation and sound-system analysis where applicable
Worked example
Assume a School classroom HVAC background level is 34 dBA. It is below the credit's 35 dBA classroom limit, but the sound-transmission conditions still need verification. Subtracting decibels is only a limit comparison, not an acoustic energy summation.1
Requirements
For standard eligible adaptations, address HVAC background noise, sound isolation, reverberation and sound reinforcement/masking using the specified standards and room-type criteria. Schools have tighter classroom HVAC criteria and sound-transmission requirements. Healthcare has separate speech/privacy/background-noise and acoustic-finish/site-noise options. Core and Shell and Retail are not listed as eligible in this edition.1
FAQ
Does an NRC product rating prove all acoustic criteria?
No. Absorption, transmission and HVAC noise are different checks, and their required scope depends on the room and adaptation.1
Sources
This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.
- LEED v4 BD+C Rating SystemUpdated July 25, 2019 · Acoustic Performance, printed/PDF pp. 136-139