For Commercial Interiors and Hospitality, meet two acoustic performance groups across occupied spaces. The ID+C Retail adaptation does not include this credit.1
Reviewed · Spot an error? Report it
Points
Commercial Interiors/Hospitality: 2 points for two compliant groups. All three groups may support an exemplary-performance point. No Retail credit is listed.1
Documents to prepare
Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.
- Preparation checklist: Occupied-space/use/privacy and adjacency schedule, acoustic calculations and representative test plan.
- Preparation checklist: Composite STC/NIC, room-specific reverberation and/or HVAC-noise evidence; masking design/commissioning if the adjustment is claimed.
Worked example
Assume all occupied spaces are documented as compliant with sound transmission and reverberation requirements. A representative private-office adjacency has composite STC 45, meeting the Table 1 private/private minimum, and measured T60 of 0.55 seconds at all three required frequencies, below 0.6. Those sample values support the documented scope, but a single room alone does not demonstrate every occupied space. With both groups fully demonstrated, pursue 2 points.1
Requirements
Meet two of HVAC background noise, sound transmission and reverberation-time requirements for all occupied spaces. Confirm compliance with representative-room calculations/measurements and/or design documentation from a person experienced in acoustics.1
HVAC background noise follows the listed ASHRAE/AHRI limits and transmission-path criteria, or a local equivalent. Sound transmission applies the adjacency-specific composite STC or NIC values in Table 1 and stated measurement methods. Qualified sound masking may reduce Table 1 values by five, except mechanical rooms, only when all masking design, level, uniformity and commissioning conditions are met.1
Reverberation time must meet the room-specific Table 2 limit at 500, 1,000 and 2,000 Hz. For example, private offices and conference rooms require T60 below 0.6 seconds, while open-plan offices require below 0.8 seconds.1
FAQ
Does this credit apply to Retail because Table 1 contains a retail adjacency?
No. The applicability list identifies Commercial Interiors and Hospitality, and the scorecard omits Retail acoustic points.1
Does meeting one acoustic group earn one point?
The stated base credit is two points for meeting two groups.1