Credit Low-Emitting Materials

Select compliant interior material categories using the category-specific emissions, content and reporting criteria. Points depend on complete category calculations, not a count of certificates.1

Points
1 to 3 points
Applies to
ID+CBD+C
Other versions
v4v5
VERTIQ reference ID
EQc2

Reviewed · Spot an error? Report it

Points

PointsRequirement
1Two compliant categories
2Three
3Three at the 90% threshold, or four compliant categories

Four categories with at least three at 90%, or five categories, may support exemplary performance.1

Documents to prepare

Prepared by VERTIQ as a checklist. Check the Reference Guide for what your review requires.

  • Preparation checklist: Complete category product register and cost, surface-area or volume denominator consistent with each category.
  • Preparation checklist: Emissions/content/formaldehyde/furniture certificates or test summaries, exposure scenarios, chemical inventory to at least 0.1% (1000 ppm) for inherently nonemitting claims where required, reused-material age and product-scope/exclusion evidence.

Worked example

Assume compliant flooring covers 920 of 1,000 m2 and compliant ceiling products cover 950 of 1,000 m2, with all other category rules met. Flooring = 920 / 1,000 x 100 = 92%; ceilings = 950 / 1,000 x 100 = 95%. Both pass their 90% category thresholds. Two compliant categories earn 1 point. This example does not claim three points from two high percentages.1

Requirements

Paints/coatings and adhesives/sealants each need at least 75% VOC-emissions compliance by volume or surface area AND 100% VOC-content compliance; a VOC budget may satisfy the content requirement. Flooring and ceilings need at least 90% compliance by cost or area. Wall panels and insulation need at least 75% by cost or area. Furniture needs at least 75% by cost, and composite wood at least 75% by cost or area. Apply each category scope and exclusions.1

The permitted compliance evidence differs by category: emissions testing, inherently nonemitting or qualifying reused material, formaldehyde evaluation or furniture testing. Reused products must be more than one year old; on-site finishes must meet emissions and content criteria. Inherently nonemitting classification considers the whole product, coatings, binders and other components. Zero VOC content alone is not an emissions test.1

Use the specified CDPH emissions and TVOC reporting criteria, accepted regional alternatives where applicable, applicable VOC-content standards, and the category-specific formaldehyde/furniture paths. Furniture cost contribution is 0.5, 1 or 1.25 according to the qualifying BIFMA sections. Retain testing/certification and exposure-scenario evidence rather than assuming a marketing label covers the product.1

FAQ

Does a zero-VOC paint label satisfy both paint tests?

No. VOC content and emissions are separate. Paints/coatings require the emissions share and 100% content compliance or the permitted budget.1

Can composite wood already counted in flooring also be counted as composite wood?

The composite-wood category excludes products covered in flooring, ceilings, wall panels or furniture. Apply the stated category boundaries.1

Sources

This reference summarizes the cited material. It does not replace the applicable rating system, addenda or a GBCI review.

  1. LEED v4.1 Interior Design and Construction GuideNovember 2025 · Low-Emitting Materials, printed/PDF pp. 151-159; ID+C scorecard printed/PDF pp. 5-6

Maintained by VERTIQ, LEED software for consultants.